EasyManua.ls Logo

Miele CVA2650 - Table 060-11: Flow Meter Pulse Rates; Table 060-12: Sensor;Switch Check Reference

Miele CVA2650
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
87
CVA 265x & CVA 266x
Number of Pulses Explanation
About 15 Water intake in order (w/o capsule)
<2 (for more than 7 seconds)
Insufficient water intake (F17: Section 060-3.8)
0 (for more than 7 seconds)
No water intake (F10: Section 060-3.7)
Table 060-11: Flow Meter Pulse Rates
Display Explanation
Page 1
Door contact switch
0 = Door open
1 = Door closed
Water container sensor
0 = Water container empty/not installed
1 = Water container filled/installed
Steam valve sensor
0 = Steam valve closed
1 = Steam valve open
Page 2
Drip tray present
0 = Drip tray not installed
1 = Drip tray installed
Drip tray full
0 = Drip tray not full
1 = Drip tray full (needs to be emptied)
Waste container present
0 = Waste container full or not installed
1 = Waste container OK and installed
Table 060-12: Sensor/Switch Check Reference
4.5.2 CVA 2652/2662
Initial requirements:
Switch off the machine.
Accessing:
Note:
The service mode must be accessed within 2 seconds.
1. Press and hold the Cup Size touchpad.
2. Press the On/Off touchpad once.
3. Release the Cup Size touchpad.
4. Press and release the On/Off touchpad 3 times; on the 3rd time, hold it
pressed in until the service mode is accessed.
Acknowledgement indicator:
The display shows Service mode in the upper left-hand corner.
Options:
Press the < or > touchpads until the desired service function is displayed;
see Table 060-13.
Press the OK touchpad.
Press the < or > touchpads until the desired option is displayed; see
Table 060-13.
Quit: Press the On/Off touchpad to switch off the appliance.