Technical Information
87
CVA 265x & CVA 266x
Number of Pulses Explanation
About 15 Water intake in order (w/o capsule)
<2 (for more than 7 seconds)
Insufficient water intake (F17: Section 060-3.8)
0 (for more than 7 seconds)
No water intake (F10: Section 060-3.7)
Table 060-11: Flow Meter Pulse Rates
Display Explanation
Page 1
Door contact switch
0 = Door open
1 = Door closed
Water container sensor
0 = Water container empty/not installed
1 = Water container filled/installed
Steam valve sensor
0 = Steam valve closed
1 = Steam valve open
Page 2
Drip tray present
0 = Drip tray not installed
1 = Drip tray installed
Drip tray full
0 = Drip tray not full
1 = Drip tray full (needs to be emptied)
Waste container present
0 = Waste container full or not installed
1 = Waste container OK and installed
Table 060-12: Sensor/Switch Check Reference
4.5.2 CVA 2652/2662
Initial requirements:
Switch off the machine.
Accessing:
Note:
The service mode must be accessed within 2 seconds.
1. Press and hold the Cup Size touchpad.
2. Press the On/Off touchpad once.
3. Release the Cup Size touchpad.
4. Press and release the On/Off touchpad 3 times; on the 3rd time, hold it
pressed in until the service mode is accessed.
Acknowledgement indicator:
The display shows Service mode in the upper left-hand corner.
Options:
Press the < or > touchpads until the desired service function is displayed;
see Table 060-13.
Press the OK touchpad.
Press the < or > touchpads until the desired option is displayed; see
Table 060-13.
Quit: Press the On/Off touchpad to switch off the appliance.