Technical Information
64
CVA 265x & CVA 266x
3.2 Fault Code Summary
Fault
Code
Cause See Section
F 1
Coffee/hot-water NTC temperature sensor short-circuited 060-3.3
F 2
Coffee/hot-water NTC temperature sensor open-circuited 060-3.4
F 3
Steam NTC temperature sensor short-circuited 060-3.6
F 4
Steam NTC temperature sensor open-circuited 060-3.6
F 10
No water intake
060-3.7
Water tank not installed
Hose/connections blocked or crimped
Water tank valve jammed/blocked
Inoperative flow meter
Inoperative coffee/hot-water pump
Hoses on ceramic valve have been swapped (connected in reverse)
F 17
Insufficient water intake
060-3.8
Water tank not installed or not installed correctly
Hose/connections blocked or crimped
Water tank valve jammed/blocked
Inoperative flow meter
Inoperative coffee/hot-water pump
Hoses on ceramic valve have been swapped (connected in reverse)
F 42
Main power frequency not registered 060-3.9
F 45
Electronic fault 060-3.10
F 47
Communication fault between electronics 060-3.11
F 71
Capsule magazine jammed
060-3.12
Inoperative capsule magazine motor
Inoperative capsule magazine motor switch
F 72
Capsule transport jammed
060-3.13
Inoperative capsule transport motor
Inoperative capsule magazine switch
F 73
Brew unit jammed
060-3.14
Inoperative brew unit motor
Inoperative brew unit position switch
F 74
Inoperative ceramic valve motor
060-3.15
Inoperative ceramic valve position switch
F 75
Capsule not ejected from brew unit 060-3.16
F 76
Capsule jammed during pressing 060-3.17
F 77
Faulty initiation of ceramic valve
060-3.18
Inoperative ceramic valve switch
F 80
Coffee/hot-water heater not heating 060-3.19
F 81
Steam heater not heating 060-3.20
F 82
Coffee/hot-water heater overheating 060-3.22
F 83
Steam heater overheating 060-3.23
Table 060-3: Fault Code Summary
3.3 Fault Code F1
Cause:
Coffee/hot-water NTC short-circuited.
Remedy:
Check/replace the coffee/hot-water NTC.