Figure 060-5: Grease
Note:
Additional information for arm replacement:
Before re-installing, mark the position of the old arm with tape and install the
new arm in the exact same position.
The cam for the brew unit drive must not be readjusted during this process.
Remove the tape afterwards.
3. Replace the capsule transport arm; see the instructions included with the
replacement arm.
4. Replace the power electronic; see Section 060-4.7.
5. Replace the capsule plate.
6. Replace the capsule magazine slide.
Cause:
Capsule transport motor defective.
Remedy:
Install a new capsule transport motor. See Section 050-4.6.
Cause:
Capsule transport switch defective.
Remedy:
Replace the capsule transport switch.
3.14 F72, F71, F75, F76 (CVA 2650/2660 Only)
A fault message, usually F72 (Capsule transport fault), is displayed. In the
fault memory, additional faults (F71: Capsule magazine fault, F75: Capsule
not ejected, or F76: Capsule jammed during pressing) were saved.
For causes and remedies, see the section corresponding to the particular fault:
F71, Section 060-3.12; F72, Section 060-3.13; F75, Section 060-3.17; F76,
Section 060-3.18.
3.15 Fault Code F73
Cause:
Brew unit jammed.
Remedy
Remove, check and clean components
Check brew unit motor
Check brew unit position sensor