Miele CVA2650 - Table 060-8: Service Functions, CVA 2650;2660; Table 060-9: Capsule Magazine Check; Table 060-10: Brew Unit Display Codes

Miele CVA2650
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
86
CVA 265x & CVA 266x
Function Option/Component Activated Description
Component test
Heater - water
3
The display shows the
temperature registered by the
NTC sensor on the selected
heater.
Heater - steam
3
Sensor/switch
test
Page 1
Door contact
Sensor/switch test
(Table 060-12)
Water container
Steam spout
Page 2
Drip tray present
Drip tray full
Waste container
Operating hours
Operating hours
Coffee/hot-water heater
Operating hours displayed
Steam heater
Number of uses
Coffee
Number of servings Hot water
Steam
Number of descale procedures performed
Number of times descale
procedure was performed
Calibration
Cancel descaling Yes/No Resets descale timer
Mains frequency
50Hz
Sets mains (line) frequency
60Hz (all US models)
Table 060-8: Service Functions, CVA 2650/2660
1
To save the fault memory, press and hold the left switch knob until the service mode is
deactivated. The fault memory is not deleted. To clear the fault memory, turn the right
switch knob until Back is displayed, and then press the right control knob.
2
To reset to the basic setting and to avoid mechanical damage, always advance to the
Initialize setting as a final step.
3
To ensure that the flow-through heater does not become too hot, causing the fuse to
melt, only press the right switch knob briefly to check whether the heater is activated.
Display Explanation Notes
Capsule magazine sensor
0 = Chamber empty Only active when the
capsule magazine
motor is activated
1 = Chamber full
Magazine position sensor
0 = Capsule magazine state
before and after the stop pulse
--
1 = Brief stop pulse for capsule
magazine motor
Magazine drawer sensor
0 = Capsule magazine drawer
not inserted
--
1 = Capsule magazine drawer
inserted
Table 060-9: Capsule Magazine Check
Display Position
Value (Approx.)
Position Explanation
046 Rest
012 Eject
169 Press (with capsule plate only)
150 Service
009 Raised end position
185 Lower end position (with capsule plate only)
Table 060-10: Brew Unit Display Codes