Technical data
107
Model PFD402, PFD405 PFD404, PFD407
Height with machine lid
Height without machine lid
835mm (adjustable+60mm)
820mm (adjustable+60mm)
835mm (adjustable+60mm)
820mm (adjustable+60mm)
Width
598mm 598mm
Depth
Depth with door open
580mm
1.180mm
598mm
1.200mm
Weight (net)
ca. 70kg ca. 70kg
Voltage, rated load, fuse rating See data plate See data plate
Mains connection cable
Approx. 1,7m Approx. 1,7m
Water connection water temperature:
Cold water/steam condenser (optional)
Hot water
Max. 20°C
Max. 60°C
Max. 20°C
Max. 60°C
Static water pressure
1.000kPa overpressure 1.000kPa overpressure
Minimum water connection flow pressure:
Cold water/steam condenser (optional)
Hot water
200kPa overpressure
200kPa overpressure
200kPa overpressure
200kPa overpressure
Recommended water connection flow pressure:
Cold water/hot water
Steam condenser (optional – connection via
cold water)
200kPa overpressure
200kPa overpressure
200kPa overpressure
200kPa overpressure
Water inlet hose
Approx. 1,7m Approx. 1,7m
Drain hose
Approx. 1,5m Approx. 1,5m
Delivery head
Min. 0,3m, max. 1,0m Min. 0,3m, max. 1,0m
Drainage length
Max. 4,0m Max. 4,0m
Operating conditions:
Ambient temperature
Maximum relative humidity
Linear decrease to
Minimum relative humidity
5°C to 40°C
80% for temperatures up to 31°C
50% for temperatures up to 40°C
10%
5°C to 40°C
80% for temperatures up to 31°C
50% for temperatures up to 40°C
10%
Storage and transportation conditions:
Ambient temperature
Relative humidity
Air pressure
-20°C to 60°C
10% to 85%
500hPa to 1060hPa
-20°C to 60°C
10% to 85%
500hPa to 1060hPa
Altitude above sea level (according to IEC/EN
60335)
Up to 2.000m* Up to 2.000m*
Protection category (according to IEC 60529) IP21 IP21
Noise emission values
Sound power in LwA
Sound pressure in LpA
Built-under machine with wooden
beam in front of plinth on Short
programme
59dB(A)
47dB(A)
Built-under machine with wooden
beam in front of plinth on Short
programme
57dB(A)
45dB(A)
WiFi standard
802.11 b/g/n
WiFi frequency band
2400-2483,5MHz
Maximum WiFi transmission power
< 100mW
Test certifications EMC, VDE, radio and television suppressed
marking Machinery Directive 2006/42/EC
UKCA mark (UK only) The Supply of Machinery (Safety) Regulations 2008
Manufacturer address Miele & Cie. KG, Carl-Miele-Straße 29,
33332 Gütersloh, Germany
* If installation site is above 2.000m, the boiling point of the wash water will be lower. For this reason, the programme
parameters may have to be adjusted.