External dosing devices
81
17.3 Programming the transfer strip
Calling up the menu
Configuration options
Terminal
Settings
Application
DETERGENT
While machine fills
For dosing devices not from Miele
Parallel to the solenoid valve
Time-controlled
For hose pumps with fixed output (e. g. ESP 166,
ESP 166C, SP 166Z)
Impulse-controlled
Integral dosing device Fluidos DT
Time-controlled V-membrane pump
Not used
WASH
Parallel to the wash pump
For dosing devices not from Miele
RINSE
Parallel to the rinse pump
For dosing devices not from Miele
Parallel to the solenoid valve
Time-controlled
For hose pumps with fixed output (e.g. SP 16K)
Impulse-controlled
Integral dosing device Fluidos DB
Time-controlled V-membrane pump
Not used