Setting the COMMAND
Switches commands depending on the command specification of the host computer side.
1
Press the key in LOCAL mode.
2
Press to select [SET UP].
3
Press the key.
4
Press the key.
5
Press to select a set value.
Set value:AUTO, MGL-Ic1,MGL-IIc
6
Press the key.
7
Press the key several times to end the setting.
Set Value Overview
AUTO
Switches to MGL-lc1 or MGL-llc automatically depending on the command of received data.
MGL-Ic1
Used when receiving the data of MGL-lc1 command.
MGL-IIc
Used when receiving the data of MGL-llc command.
• Generally, [AUTO] is acceptable, however, if the data size is too big, the normal result cannot be
gained in some cases. In such a case, change the setting value depending on the command of the
host computer side.
• When it is set to [AUTO] and the device receives data from the computer, the command name
recognized by this device is displayed on the display panel and starts cutting. If the command name is
displayed continuously after receiving data, or, [ERR16 AUTO I/F] is displayed, it is indicated that the
automatic recognition cannot be performed.
• In such a case, change it to MGL-lc1 or MGL-llc, and set the command name to cut properly. The
command automatically recognized with [AUTO] will have been valid until you perform data clear
( P.2-25), or you move the clamp lever to the front.