3-33
3
Convenient use
6
Setting function
Setting the SORTING
1
Press the key in LOCAL mode.
2
Press to select [SET UP].
3
Press the key.
4
Press to select [SORTING].
5
Press the key.
6
Press to select "ON".
7
Press the key.
8
Press to select [AUTO FEED].
When performing AUTO FEED, select "ON".
9
Press the key.
10
Press to select a set value of [AREA].
Set Value :OFF, 10 300cm (10cm step)
11
Press the key.
12
Press the key several times to end the setting.
The set values are recorded even when the power has been turned OFF.
When the set value has been changed, the data in the reception buffer is cleared.
When the sorting function is set to ON, the reception buffer capacity decreases to about 20 MB.
SQUARE CUT <ENT>
SET UP <ENT>
COMMAND < e n t >
SORT I NG < e n t >
SORT I NG : OFF
SORT I NG : ON
AUTO FEED : OFF
AUTO FEED : ON
AREA : OFF
AREA : 1 0 cm