Chapter 8 Troubleshooting
211
Error
number
Message Cause Corrective action
201 Command Error • Data other than print (RIP)
data was received, or a
problem was detected
with the print (RIP) data
received.
1. Clear the data and resend.
2. Check the USB/Ether cable connection.
"Connecting a PC to the
Product"(P. 37)
3. Use a compliant USB/Ether cable.
"Connecting a PC to the Product"(P. 37)
4. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 35)
202 Parameter Error • A problem was detected
with the print (RIP) data
received.
206 Print Mode Error • Print (RIP) data was
received with print
parameters that do not
allow printing.
• Change the output parameters and
profile using RIP software.
20A Driver Version • Printing is not possible
because the Mimaki driver
version is old.
• Install the latest Mimaki driver
available from:
https://mimaki.com/download/
inkjet.html
303 PCB MAIN ET • A problem was detected
with the main PCB.
1. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 35)
304 USB INIT ERR • A problem was detected
with the USB cable
connection.
1. Check the USB cable connection.
"Using a USB Cable"(P. 38)
2. Use a compliant USB cable. "Using
a USB Cable"(P. 38)
3. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 35)
305 USB TIME OUT
315 No resp from
XY Slitter
• A problem was detected
with the XY slitter
response.
• Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
316 XYSlitter
transmit error
• A problem was detected
with the transmission data
sent to the XY slitter.
317 XYSlitter
response error
• A problem was detected
with the response data
from the XY slitter.
318 SDcard Connection
ERR
• A problem was detected
with the SD card.
1. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 35)
401 Motor X • The X motor was
overloaded.
1. Check to confirm the media is loaded
correctly. "Loading the
Media"(P. 57)
2. Open the front cover and check for
anything that may obstruct carriage
movement.
3. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 35)
402 Motor Y • The Y motor was
overloaded.
403 X Current • An overcurrent error was
detected in the X motor.
404 Y Current • An overcurrent error was
detected in the Y motor.
406 Wiper Move Failure • The wiper origin could not
be detected.
• Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
8