Chapter 8 Troubleshooting
216
Error
number
Message Cause Corrective action
806 FW/SIO bit A communication error
was detected between the
boards.
808 FW/STP-MTR** A problem was detected
with the main PCB.
811 FW/SIO read A communication error
was detected between the
boards.
81b FW/STACK OV A problem was detected
with the main PCB.
828 PRG ERR L*****
901 Operation Error The function is disabled
due to an error.
Check the error details.
Media Undetected
Ink error
Waste Ink Tank, etc.
902 Data Remain Print (RIP) data was
received.
Switch to REMOTE mode and start
printing or clear the data and abort
printing.
90f Print Area Short The media is too small for
the print.
Replace with wider or longer media.
If the printable area is reduced due
to a shift in the origin, move the
origin to increase the size of the
printable area.
b1a PCB BaseIO A communication error
was detected between the
boards.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
b1b BaseIO PCB Vpow-s A problem was detected
with the Base IO PCB
power supply.
b1c BaseIO PCB V24
b1d BaseIO PCB V24-A
b1e PCB BaseIO-F** The Base IO PCB fuse
blow was detected.
The fuse must be replaced. Contact
your local distributor, our sales
office, or service center.
b1f PCB HDCE* A communication error
was detected between the
boards.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
b2f PCB HDCE*-F* A blown fuse on the
HDCE PCB was detected.
The fuse must be replaced. Contact
your local distributor, our sales
office, or service center.
b32 INKCT PCB V2R5 A problem was detected
with the ink supply PCB
power supply.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
b33 INKCT PCB V3R3
b3f BaseIO Unconform The PCB could not be
detected.
b49 PCB HDCE-
VHVFET[12]
A problem was detected
with the HDCE PCB
power supply.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
b4b HDCE* PCB V1R2
b4c HDCE* PCB V2R5