Chapter 8 Troubleshooting
215
Error
number
Message Cause Corrective action
631 Ink Color The ink color registered
on the IC chip is different
from the ink color filled.
Insert an ink IC chip for the correct
ink color. "Mounting the
ink"(P. 46)
650 NCU Connect A problem was detected
with the NCU connection.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
651 Replace NCU A problem was detected
with the nozzle clogging
assessment.
Clean the NCU. "NCU
Cleaning"(P. 163)
Replace the NCU if the error does
not clear. Contact your local
distributor, our sales office, or
service center.
652 NCU Nzk Chk (Hw) A problem was detected
with the nozzle clogging
assessment.
Clean the NCU. "NCU
Cleaning"(P. 163)
653 NCU Nzk Chk (Mark)
654 NCU Center Pos Printing position
adjustment failed.
655 NCU Flush Pos
656 NCU SN Adjst Sensor sensitivity
adjustment failed.
657 Replace NCU Ink Pad The NCU ink absorber is
full.
The NCU ink absorber must be
replaced. Contact your local
distributor, our sales office, or
service center.
658 NCU Sensor Lv Low The sensor's sensitivity is
impaired.
Clean the NCU. "NCU
Cleaning"(P. 163)
Replace the NCU if the error does
not clear. Contact your local
distributor, our sales office, or
service center.
65b NCU Sens Adj Err H Sensor sensitivity
adjustment failed.
65c NCU Sens Adj Err L
683 Wiper Near End The remaining amount of
cloth wiper is low.
The cloth wiper will run out soon.
Have a new cloth wiper ready.
684 Wiper End The cloth wiper has run
out.
Replace with a new cloth wiper.
"Cloth Wiper Replacement"(P. 174)
702 Thermistor Connect A problem was detected
with the thermistor
connection.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
703 Heater Brk A problem was detected
with the heater
temperature.
710 Heater Temp Error A problem was detected
with the heater
temperature.
This error will be automatically
resolved. If not, Turn off the power
on the machine and turn it on after a
while. "Turning Off the
Power"(P. 35)
801 (C)OPCODE A problem was detected
with the main PCB.
Turn off the power on the machine
and turn it on after a while.
"Turning Off the Power"(P. 35)
802 (C)SWI
803 (C)PFTCHABRT
804 (C)DATAABRT
8