Loading...
Refilling antifreeze mixed water
4-29
1
1
1
4
Routine Maintenance
Refill cooling water
If an error of lack of water, refill cooling water. To fill up its capacity, about 450cc refill is required.
1
Remove the cover of the left rear surface of the
Y bar.
Remove the screws (for ten positions) indicated with circles
in the figure and remove the cover.
2
Uncover the Feed-water inlet and the air vent.
3
Remove all remaining water in the tank.
Remove all water in the tank with a provided syringe from the
feed-water inlet.
Put the removed water into the tank with a cap, and discard it.
4
Make mixed water (antifreeze liquid: 1, water: 2) in
the attached reservoir and move it to the attached
syringe.
air vent cover
Feed-water inlet
Tank 2
Tank 1