3-8
Set the feeding amount of the Y bar
Correct the feeding amount of the Y bar.
If the feeding amount of the Y bar is not proper, stripes may appear on the printed image, thus resulting in a
poor printing.
Setting Feed Correction
A pattern for media correction is printed and a media-feeding rate is corrected.
1
Set a media. ( P.2-5)
2
Press the key in LOCAL.
3
Press the key.
4
Press the key to print a correction pattern.
5
Check the correction pattern and enter a correction
value.
Enter a correction value in "+": The boundary between the two bands is widened.
Enter a correction value in "-": The boundary between the two bands is narrowed.
• Two bands are printed in the correction pattern.
• Make adjustment so that an even color density is obtained in the boundary between the two bands.
• When you change the correction value by “20”, the band moves about 0.01mm. By
referring to this correction amount, determine the correction value.
Second band
First band
Feeding direction of Y bar
F E ED COMP .
[ ENT ]
F E ED COMP .
PR I NT [ ENT ]
** PRINTING * *
PLEASE WA I T
F E ED COMP .
= 0