12-4 Setup
Type Item Description
Screen Saver
Enable Screensaver
Select the different saver methods to the system.
After enabling the screen saver, check Mindrayto select
the image from the system. Or click [Preview] to select the
image on your own.
To set the waiting time before the system enters dormancy
status in the drop-down list beside Wait”.
The system enters screen saver automatically if the
system waiting time exceeds the screen saver already set.
Enable Standby
The system enters standby status automatically if the
system waiting time exceeds the screen saver already set
and standby time.
iVocal
Enable Voice
Response
To enable the voice response function.
Automatically shut
down waiting time
To automatically disable the voice response function after
the setting time.
12.1.3 Image Preset
Open the page via [Setup] [System] [Image].
Type
Item
Description
Reset Config.
Probe
To set the default probe model for the system from the
drop-down list.
The default parameters are applied to the new probe if
checking Use the default setting when start a new exam.
Image size
Set the standard for saving the image or using the
digital/graph printer.
Default Elasto Set the default elastography mode.
ART Flow
Max transmit time
Set the maximum duration time. Enter Color mode and
enable ART Flow; the penetrability of color image is
enhanced in this time period.
Max interval time
Set the maximum interval time. Enter Color mode and
enable ART Flow; the ART Flow is enabled again until the
interval is finished.
Parameter
Steer
To set the steer mode in B + Color + PW/CW imaging
mode.
C&(PW/CW): select to adjust the sample volume in color
mode and sample line in PW or CW mode together.
C/(PW/CW): select to adjust the sample volume in color
mode and sample line in PW or CW mode separately.
Auto Invert
The spectrum can automatically invert when the color flow
is steered to a certain angle, thus accommodating the
operators wish to distinguish the flow direction.
iScape Ruler Display
To set whether to display the iScape ruler in iScape
imaging mode.