Fail to read data
from the message
queue (Contact the
MRC.)
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
Could not create task
(Contact the MRC.)
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
The emergency button
is pressed.
Restore the emergency switch to
original position and retry. If the
error occurs repeatedly, check the
EMG signal line following the EMG
signal line check procedure.
(Main) Motion board
failure
(No response)
Power on 10 sec after machine
power off and check again.
If the error is not resolved, replace
the motion board.
Do not push gantry. The
(Main) Z-axis could
collide with the conveyor
guide.
Power on 10 sec after machine
power off and check again.
If the error occurs repeatedly,
contact the C/S engineer.
The Y-axis servo motor
failed to power on as all
of the (Main) gantries
are beyond the safety
limit.
Applied to the Mx Series Dual
Gantry. Let the gantries enter the
safety limit and check again.
Power Box Over-
Temperature Failure
Check the power box.
(Not applicable to Mx Series)
Power Box Input
Voltage Failure
Check the power box.
(Not applicable to Mx Series)
Power Box Over or
Under Voltage Failure
Check the power box.
(Not applicable to Mx Series)
(Not applicable to Mx Series)
Motion board error
(Library)
Unidentifiable error. Power on 10
sec after machine power off and
check again (MEI).
The servo motor
power is Off.
(Front X axis, Front Y1
axis)
Press the Servo On switch and try
again. If the error occurs repeatedly,
check according to the check
procedure.
The axis failed to
move to the set
position (Front Xaxis)
Try again. If the error occurs
repeatedly, contact the C/S engineer
to adjust the gain.