EasyManua.ls Logo

Mirae Mx200 - Page 355

Default Icon
681 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Solutions for Errors 5-
3
3041 -
3077
The axis failed to
move to the set
position (Front
Y1axis)
Try again. If the error occurs
repeatedly, contact the C/S engineer
to adjust the gain.
5-34
3080 -
3119
The defined position
exceeds the hardware
limit. (Front X-axis)
Lower the coordinate value at the
desired point and retry.
3120 -
3159
The axis cannot move
due to an unidentified
reason. (Front X-
axis)
Try again.
5-34
3160
3199
The axis cannot move
due to + hardware
limit. (Front Xaxis)
Check the limit sensor.
3200
3239
The axis cannot move
due to - hardware limit.
(Front Xaxis)
Check the limit sensor.
3240 -
3279
The servo motor
power is off due to
Error Limit. (Front
Xaxis)
1. Try again and, if the motor
does not move, check DMC (A),
axis1 Amp, Motor Connector and
axis1 Amp input voltage.
2. Try again and, if the motor
moves, check the Amp input voltage.
5-34
3280 -
3319
The servo motor
power is off due to
overload. (Front Xaxis)
1. Try again and, if the motor
does not move, check DMC (A),
axis1 Amp, Motor Connector and
axis1 Amp input voltage.
2. Try again and, if the motor
moves or the same error occurs
repeatedly, contact the C/S engineer
to adjust the gain.
5-34
3320
3359
The servo motor
power is off due to
Amp failure. (Front
Xaxis)
Check the Amp input voltage and
connector. Retry after Amp reset
and, if the same error occurs
repeatedly, replace the Amp or
contact the C/S engineer.
5-34
Error
Code
Message Description
Actions
References
3360
3399
The servo motor
power is off due to
Amp power off. (Front
X-axis)
Check the Amp input voltage and
connector. Retry after resetting Amp
and if the same error occurs
repeatedly, replace the Amp or
contact the C/S engineer.

Table of Contents

Related product manuals