5-10 Mx-Series Manual
7040
2 PCBs are present on
Work1.
Take out the board or adjust the board
position.
5-46
7041
2 PCBs are present on
Work2.
Take out the board or adjust the board
position.
5-46
7042
PCB not found on
Work1.
Check the conveyer belt, the sensor or
the step motor.
5-46
7043
PCB not found on Work2
Check the conveyer belt, the sensor or
the step motor.
5-46
7044
The conveyer width of
Work1 changes during
work.
Check the servo motor power and Amp.
Check the parameters.
5-46
7045
The conveyer width of
Work2 changes during
work.
Check the servo motor power and Amp.
Check the parameters.
5-46
7046-7051
Large-size PCB process
is done on the front side
of the dual conveyer.
Check the servo motor power and Amp.
Check the parameters.
5-46
8000
The requested command
cannot be executed
because the system is
busy.
Wait for a while.
8001
The specified file cannot
read.
Check again.
Error Code
Message Description
Actions
References
8002 -
8039
- direction software is
approaching limit (Front
X-axis)
The coordinate value is approaching
the (-) software limit. Increase the
coordinate value.
8042 -
8079
+ direction software is
approaching limit (Front
X-axis)
The coordinate value is approaching
the (+) software limit. Increase the
coordinate value.
8082 -
8119
Homing fail (Front X-
axis)
Press the Waiting Position Key for
homing and retry.
8123
Tray feeder Z-axis
homing cancelled
(TF Y-axis homing
incomplete)
TF Y axis homing cannot be executed
as TF Z axis homing is not completed.
Press the "waiting position" key
(DOOR) to execute homing after a
while.
8124
Shuttle Z-axis homing
cancelled
(Shuttle Y-axis homing
incomplete)
Not applicable to Mx Series
8125
Shuttle Z-axis homing
cancelled (Pallet Out)
Not applicable to Mx Series
8126
Front gantry homing
cancelled (Module Z-
axis height)
Front gantry homing cannot be carried
out as the Module Z axis is too low.
Wait for 10 sec after power off/on and
do homing again.