9 LABEL ACCESS
9.1 Data to be Specified in Commands
Structure member
When the structure member is a structure type, specify the element name by delimiting with period '.' up to the end member.
Ex.
When specifying the member, 'memberB1', of the structure member name 'memberA3' for the structure type label name
'LabelA'
Label name character string: LabelA.memberA3.memberB1
When arbitrary device is assigned, the structure type label with structure type members cannot be specified.
Timer type label, counter type label
The labels of the following data types are handled as a structure with a contact, coil, and current value for its element.
•Timer
Retentive timer
Counter
Long timer
Long retentive timer
Long counter
Specify the following element name with adding a period '.'. (UTF-16: '.' = 002E)
Ex.
For the contact of timer type label name 'Lbl1'
Label name length: 6H
Label name character string: Lbl1.S
The labels of which data type is timer, counter, retentive timer, long timer, long counter, or long retentive timer
cannot be specified with the 'batch read/write array type labels' (command: 041A, 141A).
Item Element name Example when a label name is 'Lbl1'
Contact S Lbl1.S
Coil C Lbl1.C
Current value N Lbl1.N
Item Value of code corresponds to character
Label name L b l 1 . S
UTF-16 004C 0062 006C 0031 002E 0053
ASCII code 30303443 30303632 30303643 30303331 30303245 30303533
Binary code 4C00 6200 6C00 3100 2E00 5300