412
18 COMMUNICATING USING 1E FRAMES
18.4 Read and Write Device Memory
Test in word units (random write) (command: 05)
Specify the devices and device numbers of bit devices (X, Y, M, etc.) in 16-point units randomly, and set/reset them.
Specify the devices and device numbers of word devices (D, T, C, etc.) in 1-point units randomly, and write them.
Message format
The following shows the message format of the request data and response data of the command.
Request data
Response data
There is no response data for this command.
Data specified by request data
Number of device points
Specify the number of device points to be set/reset. (Page 402 Number of device points)
When specifying bit devices, set the head device No. in multiples of 16 (0, 16, ... in decimal notation).
Fixed value
Fixed to '0'.
Specified device
Specify the device to be set/reset. (Page 397 Device codes and device numbers)
ON/OFF specification
Store the data to be written.
ASCII code Binary code
Specified device
(first point)
ON/OFF
specification
(first point)
Specified device
(nth point)
ON/OFF
specification
(nth point)
Number of device
points
(n points)
Fixed value
0
30H
0
30H
00H