476
APPENDICES APPENDIX
Appendix 6 Accessible Modules for Each Command
Commands for 1E frame
: Executable, :Not executable
*1 When accessing Universal model QCPU, use the module with a serial number whose first five digits are '10102' or later. If using a
module with a serial number whose first five digits are '10101' or earlier, access with 3E/4E frame.
In addition, when accessing a built-in Ethernet port CPU, refer to the following manual.
QnUCPU User's Manual (Communication via Built-in Ethernet Port)
*2 Read/write the devices within the range of AnACPU. The added new devices and their ranges cannot be specified.
*3 The devices that can be registered to E71 is for 1 command out of the three types of commands (06H, 07H, 1AH).
The specified device recently used by any of the above commands is registered to E71.
Function Command Access target Reference
CPU module
L Q
*1
Qn
A
A QS
Device memory Batch read Bit units 00H
*2
*2
*2

*2
Page 403 Batch read in bit units (command: 00)
Word units 01H
*2
*2
*2

*2
Page 405 Batch read in word units (command: 01)
Batch write Bit units 02H
*2
*2
*2
Page 407 Batch write in bit units (command: 02)
Word units 03H
*2
*2
*2
Page 409 Batch write in word units (command: 03)
Test (random
write)
Bit units 04H
*2
*2
*2
Page 410 Test in bit units (random write) (command:
04)
Word units 05H
*2
*2
*2
Page 412 Test in word units (random write) (command:
05)
Register
monitor
data
*3
Bit units 06H
*2
*2
*2
Page 415 Register monitor data(command: 06, 07)
Word units 07H
*2
*2
*2

Monitor Bit units 08H Page 416 Monitor in bit units (command: 08)
Page 417 Monitor in word units (command: 09)
Word units 09H 
Extended file
register
Batch read 17H Page 419 Batch read (command: 17)
Batch write 18H Page 421 Batch write (command: 18)
Test (random write) 19H Page 423 Test (random write) (command: 19)
Register monitor data
*3
1AH Page 426 Register monitor data (command: 1A)
Monitor 1BH Page 427 Monitoring (command: 1B)
Direct read 3BH Page 428 Direct read (command: 3B)
Direct write 3CH Page 430 Direct write (command: 3C)
Special function
module
Batch read 0EH Page 434 Batch read (command: 0E)
Batch write 0FH Page 436 Batch write (command: 0F)