EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Remote PAUSE (Command: 1003)

Mitsubishi Electric MELSEC iQ-R Series
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176
11 CONTROL MODULE OPERATION
11.2 Remote Operation
Remote PAUSE (command: 1003)
Perform remote PAUSE for the access target module.
The command can be executed when the switch of the access target module is RUN. In the STOP status, the
command is completed normally, however, the access target CPU will not be in PAUSE status.
Message format
The following shows the message format of the request data and response data of the command.
Request data
Response data
There is no response data for this command.
Data specified by request data
Command
*1 For C24, the additional code is added. (Page 35 Additional code (10H))
Subcommand
Mode
Select the operation when the request target module is already in remote operation by other device. (Page 167 Mode)
0001H: Do not execute forcibly
0003H: Execute forcibly
Communication example
Remote PAUSE is performed when the mode is set to "Do not execute forcibly".
Data communication in ASCII code
(Request data)
Data communication in binary code
(Request data)
ASCII code Binary code (for C24)
*1
Binary code (for E71)
ASCII code Binary code
Command Subcommand Mode
1
31H
0
30H
0
30H
3
33H
03H 10H 10H
DLE
03
H
10
H
0
30H
0
30H
0
30H
0
30H
00
H
00
H
31
H
30
H
30
H
33
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
31
H
1003 0000 0001
03
H
10
H
00
H
00
H
01
H
00
H

Table of Contents