18 COMMUNICATING USING 1E FRAMES
18.2 Details of Setting Data
395
18
End code, Abnormal code
The command processing result is stored.
End code
At normal completion, '0' is stored.
At abnormal completion, an error code of the access target is stored.
Error code indicates the content of occurred error.
If more than one error occurs at the same time, the error code detected first is returned.
For the content of error code and its corrective action, refer to the user's manual of the module used.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
Q Corresponding Ethernet Interface Module User's Manual (Basic)
MELSEC-L Ethernet Interface Module User's Manual (Basic)
Abnormal code
When an end code is '5BH', the details of abnormal content are displayed.
Setting method
■Data communication in ASCII code
Convert the numerical value to 2-digit ASCII code (hexadecimal), and send it from the upper digits.
■Data communication in binary code
Use a 1-byte value.
Normal completion
When Error code '10H' is returned
When error code '5BH' and an abnormal code '10H' (PC No. error) are returned,
ASCII code Binary code
ASCII code Binary code
ASCII code Binary code
5BH 10H