172
11 CONTROL MODULE OPERATION
11.1 Data to be specified in commands
Communication error information
A data to specify the communication error information to be initialized.
The data is equivalent to the buffer memory '0H', '1H' of MELSEC-Q/L series C24.
Specify the value (16-bit integer) in bit unit. The communication error information and its corresponding bit are as follows.
The communication error information to be initialized can be specified by turning the corresponding bit ON (1).
When the command is executed, the following corresponding bit of the buffer memory turns OFF (0).
"LED lighting status, communication error status" (Buffer memory 513 (201H), 514 (202H))
For MELSEC iQ-R series C24, specify '0'.
Setting method
■Data communication in ASCII code
Convert the numerical value to 4-digit ASCII code (hexadecimal), and send it from the upper digits.
■Data communication in binary code
Send 2-byte
*1
numerical values from lower byte (L: bits 0 to 7).
*1 For C24, the additional code may be added. (Page 35 Additional code (10H))
When initializing C/N, P/S, PRO, and SIO (bit 1 to 4) with MELSEC-Q/L series C24.
For MELSEC iQ-R series
Item b15 b14 b13 to b8 b7 b6 b5 b4 b3 b2 b1 b0
Communication error information (CH1) NEU ACK NAK C/N P/S PRO SIO SD.WAIT
Communication error information (CH2) CH1.ERR CH2.ERR
Item ASCII code Binary code
Communication error information (CH1)
Communication error information (CH2)
Item ASCII code Binary code
Communication error information (CH1)