EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Self-Station no

Mitsubishi Electric MELSEC iQ-R Series
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 ACCESS ROUTE SETTINGS
6.2 Details of Setting Data
59
6
Self-station No.
Specify this when more than one external device (m stations) and more than one C24s (n stations) are connected with the
multidrop connection.
Specify the fixed value (00H) for any cases other than multidrop connection in a m:n basis.
When external devices are connected with the m:n multidrop connection
Specify the station No. of request source external device, 0 to 31 (00H to 1FH).
For the station No. (m stations) of external devices, the value which is not set to C24 (n stations) of the multidrop connection
is used.
(The total of 'm' and 'n' is up to 32 stations.)
Station No. of a request source external device: Specify it to the self-station No.
Station No. of the connected station C24: Specify it to the station No. (Page 50 Station No.)
Setting method
Data communication in ASCII code
Convert the numerical value to 2-digit ASCII code (hexadecimal), and send it from the upper digits.
Data communication in binary code
Send a 1-byte numerical value.
Ex.
For connection other than m:n multidrop connection
For accessing with the m:n multidrop connection
Station No. assigned to a request source external device: 31 (1FH)
ASCII code Binary code
ASCII code Binary code
m:n multidrop connection
External device : Station No. (n + m - 1) < 32Request source external device : Station number specified for the Self-station No.External device : Station No. n
C24:Station number
specified for the Station No.
C24: Station No.n-1C24: Station No.0
Connected station
00
30
H
30
H
00H
31
H
46
H
1F
1FH

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals