11 CONTROL MODULE OPERATION
11.2 Remote Operation
Remote RESET (command: 1006)
Perform remote RESET for the access target module.
Execute the command after changing the status of the access target module to STOP. If the CPU module is
stopped due to the error, the command can be executed even when the switch of the CPU module is in the
position of RUN,
If a remote RESET operation enable/disable setting exists in the access target parameter, set it to enable.
Remote RESET may not be performed due to the hardware error of the access target device.
When performing remote RESET, the response message may not be returned because the access target
CPU is reset.
Message format
The following shows the message format of the request data and response data of the command.
Request data
Response data
There is no response data for this command.
Data specified by request data
Command
*1 For C24, the additional code is added. (Page 35 Additional code (10H))
Subcommand
Fixed value
The value is '0001H'.
Communication example
Perform remote RESET.
Data communication in ASCII code
(Request data)
Data communication in binary code
(Request data)
ASCII code Binary code (for C24)
*1
Binary code (for E71)
ASCII code Binary code
Command Subcommand
Fixed
values
1
31H
0
30H
0
30H
6
36H
06H 10H 10H
DLE
06
H
10
H
0
30H
0
30H
0
30H
0
30H
00
H
00
H
31
H
30
H
30
H
36
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
31
H
10 6
0
00 0
0
00 1
0
06
H
10
H
00
H
00
H
01
H
00
H