11 CONTROL MODULE OPERATION
11.5 Clear Error Information
187
11
11.5 Clear Error Information
This section explains the command to initialize LED display and error information of buffer memory, and recover the
supported device.
For details of the related LEDs, input/output signals, and buffer memory, refer to the manual of the access target module.
Turn indicator LED OFF, initialize error code (command: 1617)
Turn OFF the indicator LED of the serial communication module, and initialize the communication error information and error
codes.
The command can only be used for C24 (including multidrop connection station) connected to the external
device. It cannot be used via network.
Message format
The following shows the message format of the request data and response data of the command.
Request data
Response data
There is no response data for this command.
Data specified by request data
Command
ASCII code Binary code
Command Subcommand
Communication error
information (CH1)
Communication error
information (CH2)
1
31H
6
36H
1
31H
7
37H
17
H
16
H