130
9 LABEL ACCESS
9.1 Data to be Specified in Commands
(1) LabelA
(2) memberA3
Data communication in ASCII code
In the figure (1) and (2), set the value of "ASCII code" indicated in the table of "Value of code corresponds to character" of
each label name.
Data communication in binary code
In the figure (1) and (2), set the value of "Binary code" indicated in the table of "Value of code corresponds to character" of
each label name.
Item Value of code corresponds to character
Label name L a b e l A
UTF-16 004C 0061 0062 0065 006C 0041
ASCII code 30303443 30303631 30303632 30303635 30303643 30303431
Binary code 4C00 6100 6200 6500 6C00 4100
Item Value of code corresponds to character
Label name m e m b e r A 3
UTF-16 006D 0065 006D 0062 0065 0072 0041 0033
ASCII code 30303644 30303635 30303644 30303632 30303635 30303732 30303431 30303333
Binary code 6D00 6500 6D00 6200 6500 7200 4100 3300
30
H
30
H
30
H
36
H
30
H
30
H
30
H
32
H
30
H
30
H
30
H
38
H
00 6000 20 00 80(1) (2)
Label points Label name length Label name Label name length Label name
Label specification (1st point) Label specification (2nd point)
02
H
00
H
06
H
00
H
08
H
00
H
(1) (2)
Label points Label name length
Label name
Label name length
Label name
Label specification (1st point) Label specification (2nd point)