12 FILE CONTROL
12.5 File Creation and Deletion
225
12
Communication example (files for MELSEC iQ-R series)
Delete the file under the following conditions:
Password: A to Z (26 characters)
Drive No.: 4
The file name is as follows:
(1) LINE.CSV (8 characters)
Data communication in ASCII code
(Request data)
In the figure (1), set the value of "ASCII code" in the table of "Value of code corresponds to character" in "File name".
Data communication in binary code
(Request data)
In the figure (1), set the value of "Binary code" in the table of "Value of code corresponds to character" in "File name".
Item Value of code corresponds to character
File name L I N E . C S V
UTF-16 004C 0049 004E 0045 002E 0043 0053 0056
ASCII code 30303443 30303439 30303445 30303435 30303245 30303433 30303533 30303536
Binary code 4C00 4900 4E00 4500 2E00 4300 5300 5600
1822
31H 38H 32H 32H
0040
30H 30H 34H 30H
001A
30H 30H 31H 41H
CD Z
43H 44H 54H
AB
41H 42H
0004
30H 30H 30H 34H
0008
30H 30H 30H 38H
(1)
Number of
password characters
Subcommand Password
Number of file name
charactersDrive No. File name
22H 18H 40H 00H 04H 00H 0DH 00H
CD Z
43H 44H 5AH
AB
1AH 00H 41H 42H
(1)
Subcommand
Number of
password characters
Drive
No.
Number of file name
charactersPassword File name