17 COMMUNICATING USING 1C FRAMES
17.4 Device Memory Read and Write
369
17
Monitor (bit units) (command: MB, MJ)
Monitor the registered bit devices (X, Y, M, etc.).
The bit device memory registered with BM command is monitored using MB command.
The bit device memory registered with JM command is monitored using MJ command.
Request data
Command
Message wait: Specify the delayed time of the response transmission. (Page 347 Message wait)
Response data
The value of read device is stored in bit units. (Page 74 Read data, write data)
Communication example
Monitor bit devices specified with monitor data registration under the following conditions.
Message wait: 0 ms
Registered devices for monitoring: 3 points (3 bits) of contacts for X040, Y060 and T123.
(Request data)
When using MB (ACPU common command)
When using MJ (AnA/AnUCPU common command)
(Response data)
ACPU common AnA/AnUCPU common
Message wait
Command
MB
4DH 42H
MJ
4DH 4AH
Monitoring result ( For the
number of device points )
MB
4D
H
42
H
0
30
H
Message wait
MJ
4D
H
4A
H
0
30
H
Message wait
(X040) (Y060)
1
31H
0
30H
1
31H
Monitoring result ( For the number of device points )
(Contact of T123)