400
18 COMMUNICATING USING 1E FRAMES
18.4 Read and Write Device Memory
List of devices (AnUCPU, QnACPU)
Specify the device within the range of AnACPU.
Page 397 Considerations when reading/writing data to module other than ACPU module
: Accessible, : Not accessible, : No device
Do not write data to the devices which cannot be written in the range of the special relays (M9000 to M9255)
and special registers (D9000 to D9255). For details on the special relays and special registers, refer to the
programming manual of ACPU.
For L and S, perform accessing by specifying 'M' (For example, to access L100, specify M100.)
Device Device range Device number A2US
A2U
A2US-S1
A2USH-S1
A2U-S1
A3U
A4U
Q2A
Q2AS
Q2ASH
Q2A-S1
Q2AS-S1
Q2ASH-
S1
Q3A
Q4A
Q4AR
Input X0 to X1FF 0000H to 01FFH 
X200 to X3FF 0200H to 03FFH 
X400 to X7FF 0400H to 07FFH 
Output Y0 to Y1FF 0000H to 01FFH 
Y200 to Y3FF 0200H to 03FFH 
Y400 to Y7FF 0400H to 07FFH 
Internal relay
(Including latch relay and step relay)
M0 to M8191 0000H to 1FFFH 
M9000 to M9255
(SM1000 to
SM1255)
2328H to 2427H 
Annunciator F0 to F2047 0000H to 07FFH 
Link relay B0 to BFFF 0000H to 0FFFH 
Timer Current value T0 to T2047 0000H to 07FFH 
Contact T0 to T2047 0000H to 07FFH 
Coil T0 to T2047 0000H to 07FFH 
Counter Current value C0 to C1023 0000H to 03FFH 
Contact C0 to C1023 0000H to 03FFH 
Coil C0 to C1023 0000H to 03FFH 
Data register D0 to D6143 0000H to 17FFH 
D9000 to D9255
(SD1000 to SD1255)
2328H to 2427H 
Link register W0 to WFFF 0000H to 0FFFH 
File register R0 to R8191 0000H to 1FFFH 