420
18 COMMUNICATING USING 1E FRAMES
18.5 Read and Write Extended File Register
Communication example
Read the extended file registers in the CPU module with E71 mounted under the following conditions.
• Block number: No.2
• Device number: R70
• Number of device points: 3 points
■Data communication in ASCII code
(Request data)
(Response data)
■Data communication in binary code
(Request data)
(Response data)
35
H
32
H
32
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
34
H
36
H
33
H
30
H
30
H
30
H
30
H
30
H
32
H
30
H
5220 000000 460002
0300
Block No. Device number
Number of device points
31
H
32
H
33
H
34
H
38
H
37
H
36
H
35
H
30
H
31
H
33
H
46
H
013F87651234
Data for the number of specified device points
(R70 in No.2) (R71 in No.2) (R72 in No.2)
03
H
00
H
46
H
00
H
00
H
00
H
20
H
52
H
02
H
00
H
Number of device points
Block
No.
Device number
12
H
34
H
87
H
65
H
01
H
3F
H
Data for the number of specified device points
(R70 in No.2) (R72 in No.2)
(R71 in No.2)