EasyManua.ls Logo

Mitsubishi FX-20P-E - Page 88

Mitsubishi FX-20P-E
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX-20P-E Handy programming panel Test 9
9-8
Example:Changing the set value from the list program monitor
Changing the set value of "OUT C0" in the step No. 15 from "K10" to "D20"
M 15
18
19
OUT
LD
AND
C 0
K10
M 0
M 1
In the step 1)
Display example
In the step 2)
M 15
18
19
OUT
LD
AND
C 0
K10
M 0
M 1
In the step 4)
T15
18
19
OUT
LD
AND
C 0
D 20
M 0
M 1
1)
2)
3)
Key operation
4)
Display the step No. 15 by
the list program monitor.
D 2 0
5)
GO
Move the line cursor to the line of the set value.
MNT/TEST

Table of Contents

Related product manuals