6 Function Code Table NICE7000 User Manual
- 114 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-17
Fire emergency
function selection 1
Bit0: Fire emergency 1 door 1
valid
Bit1: Fire emergency 1 door 2
valid
Bit2: Nearest oor for re
emergency
Bit3: Opposite door control
unchanged
Bit4: Reserved
Bit5: Retentive at power failure
Bit6 to Bit7: Reserved
Bit8: Fire emergency indicator
blinking at re emergency 1
Bit9: Fire emergency indicator
steady ON at re emergency 1
Bit10: Fire emergency tone
discontinuous prompt at re
emergency 1
1283
-
F6-18
Fire emergency
function selection 2
Bit0: Fire emergency 2 door 1
valid
Bit1: Fire emergency 2door 2 valid
Bit2: Entering reghter operation
state automatically
Bit3: Fireghter switch
Bit4: Fire emergency switch
switchover
Bit5 to Bit6: Reserved
Bit7: Low speed door close
Bit8: Fire emergency indicator
blinking at re emergency 2
Bit9: Fire emergency indicator
steady ON at re emergency 2
Bit10: Fire emergency tone
prompt at intervals at re
emergency 2
Bit11: Exiting re emergency at
any oor
1291
-