6 Function Code Table NICE7000 User Manual
- 116 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-27
Emergency
evacuation function
selection
Bit0: Door 1 valid
Bit1: Door 2 valid
Bit2: Emergency evacuation time
protection
Bit3: Manual control
Bit4: Buzzer tweeting
Bit5: HCB output
Bit6: Shorting stator braking mode
switched over to controller drive
Bit7: Mode of shorting stator
braking mode switched over to
controller drive
Bit8: Emergency evacuation exit
mode
3
-
F6-28
Inspection function
selection
Bit0: Fire emergency prompt in
inspection state
Bit1: Door lock disconnected
after inspection switched over to
normal running
Bit2 to Bit4: Reserved
Bit5: Door open and close once
after inspection turned to normal
or rst-time power-on
33
-
F6-30
VIP function
selection
Bit0: VIP1 function
Bit1: VIP2 function
Bit2: VIP enabled by hall call (at
VIP oor)
Bit3: VIP enabled by button at VIP
oor
Bit4: VIP enabled by terminal
Bit5: VIP enabled by button at any
oor
Bit6: VIP enabled by car call
Bit7: Security oor auto enable
Bit8: Number of VIP car calls
limited
Bit9: VIP auto exit
Bit10 to Bit13: Reserved
Bit13: Hall call saved
Bit14: Auto door close
Bit15: Reserved
0
-
F6-31
VIP oor 1 0 to F6-00
0
-
F6-32
VIP oor 2 0 to F6-00
0
-