NICE7000 User Manual 6 Function Code Table
- 121 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
FA-15
Program control
selection
Bit0: Super short oor function
Bit1: Up slow-down not reset for
super short oor
Bit2: Down slow-down not reset
for super short oor
Bit3: Cancelling monitoring at
leveling and slow-down
Bit4: Slow-down stuck detection
Bit5: Canceling 45s time limit at
shaft auto-tuning
Bit6: Leveling adjustment
0
-
Group Fb: Door function parameters
Fb-00
Number of door
machine(s)
1–2
1
-
Fb-01
Door function
selection
0–65535
0
-
Fb-02
Service oors 1 of
door machine 1
0–65535
65535
-
Fb-03
Service oors 2 of
door machine 1
0–65535
65535
-
Fb-04
Service oors 3 of
door machine 1
0–65535
65535
-
Fb-05
Service oors 4 of
door machine 1
0–65535
65535
-
Fb-06
Service oors 1 of
door machine 2
0–65535
65535
-
Fb-07
Service oors 2 of
door machine 2
0–65535
65535
-
Fb-08
Service oors 3 of
door machine 2
0–65535
65535
-
Fb-09
Service oors 4 of
door machine 2
0–65535
65535
-
Fb-10
Door open
protection time
5–99
10
s
Fb-11
Forced door close
time
5–99
15
s
Fb-12
Door close
protection time
5–99
15
s
Fb-13
Door re-open times 0–20
0
-