6 Function Code Table NICE7000 User Manual
- 126 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
Group FH: Close-loop parameters
FH-00
Group FH security
password
0–65535
01000
-
FH-01
Encoder type
0: SIN/COS encoder, absolute
encoder
1: UVW encoder
4: ABZ incremental encoder
0
-
FH-02
Encoder pulses per
revolution
0–10000
2048
PPR
FH-03
Encoder wire-
breaking detection
time
0–10.0
2.1
s
FH-04
Encoder
initial angle
(synchronous
motor)
0.0–359.9
0
Degree
(°)
FH-05
Encoder
current angle
(synchronous
motor)
0.0–359.9
0.0
Degree
(°)
FH-06
Wiring mode 0–15
0
-
FH-08
Zero drift 1 0–65535
0
-
FH-09
Zero drift 2 0–65535
0
-
FH-10
Zero drift 3 0–65535
0
-
FH-11
Zero drift 4 0–65535
0
-
FH-17
Position of up slow-
down 1
0.000–300.00
0.00
m
FH-18
Position of down
slow-down 1
0.000–300.00
0.00
m
FH-19
Position of up slow-
down 2
0.000–300.00
0.00
m
FH-20
Position of down
slow-down 2
0.000–300.00
0.00
m
FH-21
Position of up slow-
down 3
0.000–300.00
0.00
m
FH-22
Position of down
slow-down 3
0.000–300.00
0.00
m
FH-29
Position switch
signal delay
0–200
0
ms
Group FL: Extension terminal function parameters
FL-00
CTB input type 0–511
320
-