NICE7000 User Manual 6 Function Code Table
- 127 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
FL-01
HCB-B:JP1 input
0: Invalid
1: Light-load signal
2: Half-load signal
3: Door 2 selection
4: Door 2 restricted
5: Door 1 safety edge
6: Door 2 safety edge
7: Single/Double door selection
8: Fire emergency oor switchover
9: Fire emergency start signal
0
-
FL-02
HCB-B:JP2 input
0
-
FL-03
HCB-B:JP3 input
0
-
FL-04
HCB-B:JP4 input
0
-
FL-05
HCB-B:JP5 input
0
-
FL-06
HCB-B:JP6 input
0
-
FL-07
HCB-B:A1 output
0: Invalid
1: Fault output
2: Non-door zone stop output
3: Non-service state output
4: Fire emergency output
5: Power failure emergency output
6: Door lock valid
7: Night output signal
8: Fire emergency indicator
9: Fire emergency tone
0
-
FL-08
HCB-B:A2 output
0
-
FL-09
HCB-B:B1 output
0
-
FL-10
HCB-B:B2 output
0
-
FL-11
HCB-B:C1 output
0
-
FL-12
HCB-B:C2 output
0
-
FL-13
HCB-B:C3 output
0
-
FL-14
HCB-B:C4 output
0
-
FL-15
HCB-B:C5 output
0
-
FL-16
HCB-B:C6 output
0
-
FL-17
HCB:JP1 input
1: Elevator lock signal
2: Fire emergency signal
3: Current oor forbidden
4: VIP oor signal
5: Security oor signal
6: Service oor switchover
7: Parking oor switchover
8: Down collective selective
switch
9: Peak service switch
10: Fire emergency oor
switchover
1
-
FL-18
HCB:JP2 input
2
-
FL-19
HCB:JP1 output
0: Invalid
1: Up arrival indicator
2: Down arrival indicator
3: Fault output
4: Non-door zone stop output
5: Non-service state output
6: Buzzer output
1
-
FL-20
HCB:JP2 output
2
-

Table of Contents