7 Description of Function Codes NICE7000 User Manual
- 176 -
The 16 binary bits correspond to the running parameters listed in the following table.
Bit Parameter Name Default Bit Parameter Name Default
Bit0
Speed reference
1 Bit8
Output frequency
1
Bit1
Logic information
1 Bit9
Output torque
1
Bit2
Curve information
1 Bit10
Torque current
1
Bit3
Pre-torque current
1 Bit11
Output power
1
Bit4
Feedback speed
1 Bit12
Present position
1
Bit5
Bus voltage
1 Bit13
Communication interference
1
Bit6
Output voltage
1 Bit14
Encoder interference
1
Bit7
Output current
1 Bit15
Car load
1
The method of setting FA-01 is as follows:
If a bit is set to 1, the parameter indicated by this bit is displayed; if this bit is set to 0, the
parameter is not displayed.
Convert the sum of binary values of all 16 bits to decimal, and then set the decimal on the
operation panel.
Figure 7-5 Converting binary value of FA-01 to decimal
By default, all 16 parameters are displayed; therefore, the value set on the operation panel
is:
1 + 2 + 4 + ...32768 = 65535
The method of viewing FA-01 is as follows:
In the running state, the display of FA-01 is a decimal value. You can press
to view the