- 177 -
parameter indicated by each bit circularly.
Figure 7-6 Shift between parameters displayed in the running state
Logic information
Curve information
Pre-torque current
Feedback speed
Bus voltage
Output voltage
Output current
Output frequency
Torque current
Output power
Speed reference
Output torque
Shift between parameters
displayed in the running state
Present position
Car load
Encoder interference
Communication
interference
Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8 Bit9 Bit10 Bit11 Bit12 Bit13 Bit14 Bit15
Function Code Parameter Name Setting Range Default Unit Property
FA-02
Display in stop state 1–65535
4095 - ☆
It is used to set the running parameters displayed on the operation panel when the elevator
is in the stop state.
FA-02 includes 16 binary bits, each dening a parameters. A total of 16 parameters can be
can be displayed at stop.
The 16 binary bits correspond to the parameters listed in the following table.
Bit Parameter Name Default Bit Parameter Name Default
Bit0
Rated elevator speed
1 Bit8
Encoder signal 3
1
Bit1
Bus voltage
1 Bit9
Encoder signal 4
1
Bit2
Current oor
1 Bit10
Encoder signal 5
1
Bit3
Current position
1 Bit11
Encoder signal 6
1
Bit4
Car load
1 Bit12
Reserved
0
Bit5
Slow-down distance
1 Bit13
Reserved
0
Bit6
Encoder signal 1
1 Bit14
Reserved
0
Bit7
Encoder signal 2
1 Bit15
Reserved
0
The method of setting and viewing FA-02 is similar to that of FA-01.