12.2.2.4
Desk Mount
To use the repeater as a desk mount, install mounting brackets (PN: 07009401001) at a 90 degree
angle as shown in Figure 80: Desk Mount Installation on page 124 using two M4 screws (PN:
0310907A99) for each bracket using a
T20 Torx driver at 15 in-lb (1.7 N-m). Then push a rubber foot (PN: 75009498001) into each bracket as
shown in Figure 80: Desk Mount Installation on page 124. Next push two rubber feet (PN:
75009502001) into the base frame also shown in Figure 80: Desk Mount Installation on page 124.
Figure 80: Desk Mount Installation
12.3
Electrical Connections
After the repeater equipment has been mechanically installed, electrical connections must be made.
This involves making the following connections to:
• power supply,
•
antenna coax cables
• system cables, and
• grounding
Figure Figure 81: Back Panel Connector Names and Locations on page 124 shows the position of the
repeaters external connectors located on the back panel of the repeater. Table 42: Connector Type
and Primary Function on page 124 identifies the connector types as well as a given connector's
primary function.
Figure 81: Back Panel Connector Names and Locations
Table 42: Connector Type and Primary Function
Location Connector Type Function(s)
1 C14 (IEC 60320) AC Power Inlet of Repeater Power Switch
2 Molex 42818-0212 DC Power Inlet and DC Charger Outlet
Table continued…
Chapter 12: SLR 5000 Series Installation
Motorola Solutions Confidential