11
Alignment is complete.
NOTICE:
• See Figure 10: Audio Block Diagram on page 52 for details regarding the audio and
data flow.
• Set the modulation limit to 92% to compensate for any additional deviation incurred by
the transmitter VCOs over temperature.
• The Tuner application always aligns the Modulation Limit parameter in a 12.5 kHz
channel spacing regardless of the CPS setting, so calculate the tuning % RSD
accordingly. If the CPS is set for 25 kHz operation, the repeater will automatically
scale the deviation by a factor of two when outside of the Tuner environment.
10.7.4
Verification (with Tx Data or PL)
See Verification (with no Tx Data and no PL) on page 90 with the following exceptions:
• The same Tx data signal level determined (obtained from Step 8 in Tuning Procedure (with Tx Data
or PL) on page 91), is applied to Pin 13 during the validation process.
• Pin 22 may be used instead of Pin 1, depending on the recommendation by the manufacturer of the
third party controller.
10.8
Changing to Battery Charger Only Mode
This feature allows you to change operation mode from "Normal Mode" to "Battery Charger Only"
mode.
Prerequisites: Power the repeater from an AC source and connect the system to a laptop with USB
cable. Run the MOTOTRBO Tuner application.
Procedure:
1 Connect the battery to the repeater's DC connector.
2 Click the Read button.
3 Under the Device Information main menu, click the Battery Charger Only Mode button.
Testing procedure begins. When testing procedure ends, the display shows All functions
other than the battery charger will be disabled. Do you wish to
continue?
4 Do one of the following:
• Click Yes. The display shows The Unit is in battery charger only mode.
Please remove power for 15 seconds to exit.
• Click No to return to the main menu.
Once remove battery, remove AC power and DC power for 15 seconds to restore full system
functionality. The system only detects and charges another battery after restoring full system
functionality.