MSA AUER
MSA
Installation
SUPREMATouch
177
US
Technical Data:
Systems with peripheral data logging (satellites) and LWL converters
In the case of great distances or electromagnetic disturbances to be expected, the optical fibre
(LWL) transfer can be used. In this case, no potential equalization between base station and the
satellite will occur either. The LWL converter changes electrical signals to optical signals, which
are no more disturbed by other electrical signals. A star-shaped network topology is compulsory,
to avoid critical values of the CAN bus capacity.
Supply voltage Nominal voltage 24 VDC±10 %
Current consumption (at 20 °C): typ. 85 mA
Plug connector X 100 (DSUB9, plug) - serial interface
X 101 (6-pin screw connector UEGM) - 24 V supply voltage
X 400-SIO331 (Combicon design, 5-pin MSTB2.5/5-5.08) - CAN or De-
viceNet NET 0
X 400-SIO-CAN2 (Combicon design, 5-pin MSTB2.5/5-5.08) - CAN or
DeviceNet NET 1)
Temperature range 5 ... 50 °C environmental temperature
Humidity 90% max., noncondensing
Dimensions of the
cabinet (W x H X D)
Width: 40 mm, Height: 85 mm, Depth: 83 mm (including mounting rail and
protruding connector DSUB9, without CANDeviceNet plug)
Weight approx. 200 g