Pistons and Connecting Rods
7 - 15
9.612.0.006.7160 - 05/04
With the bore gauge at 90° from the partition of the
connecting rod, reset the dial indicator gauge, remove
one of the connecting rod bolts and measure its
pre-tension.
Pre-tension = 0.06 - 0.12 mm