Lubrication System
12 - 3
9.612.0.006.7160 - 05/04
Disassembly Notes
Remove lubricant oil cooler removing only the
hexagonal bolts.
During the removal of the oil cooler, do not remove the
"Torx" bolts, avoiding the mixture of lubricant oil in the
cooling system.
The bolts "Torx" types require a special driver for their
removal and, if necessary, only can be removed when
the oil cooler is removed from the engine block.
Inspections and Measurements
Clean and check the oil suction pipe in the engine for
cracks or blockings.
Change the sealing ring of the oil suction pipe.