V10/V7.5/V5/V3.5 Installation and Operation Manual Page 3-25
Section 3 Operating Instructions Issue 3.5
3.6.8 Select Metered Parameters
For monitoring and troubleshooting
convenience, you can change the main
screen to display any three of the following:
* denotes used only in V10/V5
** denotes used only in V10/V7.5
*** denotes used only in V7.5/V3.5
**** denotes used only in V7.5
***** denotes used only in V10
• Forward Power
• Reflected Power
• PA Voltage
• Total PA Current
• Reject Power (O/P or final output) **
• Reject Power (A-C or A-D output)
• Reject Power (E-G or E-H output) **
• Reject Load Temperature (A-B)
• Reject Load Temperature (B-C) ***
• Reject Load Temperature (C-D) *
• Reject Load Temperature (E-F) **
• Reject Load Temperature (F-G) ****
• Reject Load Temperature (G-H) *****
• IPA Input Power (RF drive)
• IPA Forward Power
• IPA Reflected Power
• IPA PA Voltage
• Intake Temperature
• Exhaust Temperature
• Temperature Rise
• Controller Temperature
• Fan Voltage
• Combiner Top Fan Speed
• Combiner Bottom Fan Speed
• +2.5 V Reference Voltage
• +5 V Power Supply Voltage
• +15 V Power Supply Voltage
• –15 V Power Supply Voltage
• Efficiency (Dc to RF)
• VSWR
(a) From the main menu, highlight Meter
Presets (using f and g) and press
Select. A list of possible metered
parameters will be displayed (two at a
time, in the default display order of the
main screen).
(b) Press Edit to select the parameter to edit
and use f and g to scroll and select the
parameter to be monitored in its place.
The parameter order will follow the
default display order.
(c) Continue changing the main screen’s
displayed parameters by pressing Edit
on the field to be changed. Press Save to
store the selection.
(d) Press Back to return to previous screen.
3.6.9 Set Real Time Clock
Default display
order shown.
Meter names
not exactly as
indicated on
GUI
Main Menu
Software Version
Meter Presets
Real Time Clock
Ext Meter & Contrast
Ext Analog Samples
Select Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Software Version
Meter Presets
Real Time Clock
Ext Meter & Contrast
Ext Analog Samples
Select Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Real Time Clock
Time Day Date
11:39:59 Thu 25/May/2006
Edit Back
11:26 98.10MHz 0.00kW 1 EXA IPAA/A FanA
Real Time Clock
Time Day Date
11:39:59 Thu 25/May/2006
Edit Back
11:26 98.10MHz 0.00kW 1 EXA IPAA/A FanA
Meter Presets
Fwd Power 0 kW
06.00
Refld Power 0 W
0600
Edit Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Meter Presets
Fwd Power 0 kW
06.00
Refld Power 0 W
0600
Edit Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Power Control
Module Status
Events Log
Software Version
Meters Presets
Select Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Power Control
Module Status
Events Log
Software Version
Meters Presets
Select Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA