Item No. Item Input Data Default Note
13 Loss-Of-Signal Detection Limit
If the transmit/receive voltage is
less than the setting in 10-03-13,
the system considers this as
Loss-Of-Signal and the PRI does
not come up. Note that there are
different values based on the
setting in 10-03-12 for the PRI.
0 = Level 0 (lowest sensitivity)
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
5 = Level 5
6 = Level 6
7 = Level 7 (highest sensitivity)
2
14 Service Protocol for S-point 0 = Keypad facility
1 = Specified Protocol for Aspire system
0
15 Call Busy Mode for S-point 0 = Alerting
1 = Disconnect
0
16 Two B-Channel Transfer for
PRI Service
0=off
1=on
0
17 ISDN Ringback Tone
System can provide ringback
tone, by setting 10-03-17 is set to
1 : Enable.
0=Disable
1=Enable
0
18 Type of Number
ISDN Protocol definition.
Select the number type for the
ISDN circuit.
0 = Unknown
1 = International number
2 = National number
3 = Network Specific number
4 = Subscriber number
5 = Abbreviated number
0
19 Numbering Plan Identification
ISDN Protocol definition.
Select the Numbering Plan used
for the ISDN circuit.
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering plan
5 = Private numbering plan
0
20 Network Exchange Selection
Select the ISDN protocol for the
ISDN circuit
0 = Standard (same as NI-2)
1 = reserved
2 = reserved
3 = DMS (A211)
4 = 5ESS
5 = DMS (A233)
6 = 4ESS
7=NI-2
0
21 Number of Ports 0 = Auto
1=4Ports
2=8Ports
3=12Ports
4=16Ports
5=20Ports
6=24Ports
7=28Ports
0
22 QSIG Operation Mode 0=Disable
1=Enable
0 (V1.5 Deleted)
For PRI (T1) PKG Setup
Physical Port Number 01 ~ 24
Item No. Item Input Data Default
01 Logical Port Number
The start port number of a T1 line is dis-
played, and 24 logic ports are automatically
assigned to a DTI (T1) line.
1 ~ 126 0
02 T1 Signal Format Selection 0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
0
03 Zero Code Suppression 0 = B8ZS
1 = AMI/ZCS
0
ISSUE 1.1SL1000
Program
10
Program 10 : System Configuration Setup2-8