Required Component(s)
082U-B1
Related Features
ISDN Compatibility
Paging, External
Single Line Terminals
Guide to Feature Programming
The programs listed below indicate the most commonly used programs required for this feature. The
programs are listed in the order that the installer should follow. Refer to the PCPro wizards for further
detailed programming.
• When a * is listed next to the Program Number it indicates a program that MUST be set (from a
default state) for this feature to be enabled.
Program
No.
Program Name Input Data Default
10-03-05 * ETU Setup - ETU Setup (LTA/LCA) - 1: Door
Phone
0 = SLT
1 = Door Phone
0
32-02-01 * Door Box Ring Assignment - Extension Number Maximum eight digits Door Box Ringing
Member 1 = 101
Other : No Setting
32-03-01 Door Box Basic Setup - Chime Pattern 0 = None
1 = Door Box Ring 1
2 = Door Box Ring 2
3 = Door Box Ring 3
4 = Door Box Ring 4
5 = Door Box Ring 5
6 = Door Box Ring 6
Door Box 1 = 1
Door Box 2 = 2
Door Box 3 = 3
Door Box 4 = 4
Door Box 5 = 5
Door Box 6 = 6
32-04-01 Door Box Name Setup - Door Box Name Up to 12 characters Door Box Name 1 =
DOOR-1
Door Box Name 2 =
DOOR-2
:
Door Box Name 6 =
DOOR-6
10-61-01 Relay Port Setup - Relay Port 1 (Relay Type) 0 = No Setting
1 = External MOH
2 = BGM resource
3 = External Speaker
4 = Door Phone
0
10-61-02 Relay Port Setup - Destination Selection 1 [In case 10-61-01 is 1 or 2] = Not
Use
[In case 10-61-01 is 3] = 1-3 Ex-
ternal Speaker message No
[In case 10-61-01 is 4] = 1-6
Door Phone No
0 (Not Used)
10-61-03 Relay Port Setup - Relay Port 2 (Relay Type) 0 = No Setting
1 = External MOH
2 = BGM resource
3 = External Speaker
4 = Door Phone
0
SL2100 ISSUE 1.0
1-292
Door Box
D