Program
No.
Program Name Input Data Default
10-61-04 Relay Port Setup - Destination Selection 2 [In case 10-61-01 is 1 or 2] = Not
Use
[In case 10-61-01 is 3] = 1-3 Ex-
ternal Speaker message No
[In case 10-61-01 is 4] = 1-6
Door Phone No
0 (Not Used)
32-01-01 Door Box Timers Setup - Door Box Answer Time 0 ~ 64800 seconds 30 seconds
32-01-02 Door Box Timers Setup - Door Lock Cancel Time 0 ~ 64800 seconds 10 seconds
32-03-02 Door Box Basic Setup - CODEC Transmit Gain
Setup
1 ~ 63 (- 15.5 dB ~ + 15.5 dB) 32
32-03-03 Door Box Basic Setup - CODEC Receive Gain
Setup
1 ~ 63 (- 15.5 dB ~ + 15.5 dB) 32
11-12-36 Service Code Setup (for Service Access) - Door
Box Access
0~9,
, # Maximum of 8 digit 702
32-01-03 Door Box Timers Setup - Off-Premise Call For-
ward by Door Box Disconnect Timer
0 ~ 64800 seconds 60 seconds
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
15-03-19 Single Line Telephone Basic Data Setup - Door
Phone Number
1 ~ 6 0
Operation
To call a Door Box:
Multiline Terminal
1. Press Speaker key.
2. Dial 702.
3. Dial Door Box Number (1~6).
Single Line Terminal
1. Lift the handset.
2. Dial 702.
3. Dial Door Box Number (1~ 6).
To activate the Door Box strike:
Multiline Terminal
1. While talking to the Door Box, press Flash key.
ISSUE 1.0
SL2100
Features and Specifications Manual 1-293