Program
No.
Program Name Input Data Default
11-15-14 Service Code Setup, Administrative (for Special
Access) - Modem Access
0~9,
, # Maximum of 8 digit 740
22-02-01 Incoming Call Trunk Setup - Trunk Service Type 0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = Tie Line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID (DDI) Mode Switching
0
22-07-01 DIL Assignment - Number of Transferring Desti-
nation
Maximum of 8 digits (0 ~ 9,
, #) No Setting
90-02-01 Programming Password Setup - User Name Maximum 10 characters Refer to the Program-
ming Manual for the
default values.
90-02-02 Programming Password Setup - Password Up to eight digits Refer to the Program-
ming Manual for the
default values.
90-02-03 Programming Password Setup - User Level 0 = Prohibited User
2 = IN (Installer Level)
3 = SA (System Administrator
Level 1)
4 = SB (System Administrator
Level 2)
5 = UA (User Programming Ad-
minister Mode Level 1)
Refer to the Program-
ming Manual for the
default values.
90-26-01 Program Access Level Setup - Maintenance Lev-
el
Level 1 = MF Level
Level 2 = IN Level
Level 3 = SA Level
Level 4 = SB Level
Refer to the Program-
ming Manual for the
default values.
90-28-01 User Programming Password Setup - Password Fixed four digits 1111
10-62-01 NetBIOS Setting - NetBIOS Mode 0 = Disabled
1 = Enabled
1
10-62-02 NetBIOS Setting - NetBIOS Name Maximum 15 characters SL2100
Operation
None
PCPro and WebPro Comparison
The table below gives a quick feature comparison of PCPro and WebPro.
Feature
Feature Applica-
tion
Comments
PCPro WebPro
Installation Program Y -
SL2100 ISSUE 1.0
1-702
PC Programming
P