2. Wait for any data in cache memory to be written to the drives.
The green Cache Active LED on the back of each controller is on when cached data needs to
be written to the drives. You must wait for this LED to turn off.
3. From the Home page of SANtricity System Manager, select View Operations in Progress.
4. Wait for all operations to complete before continuing with the next step.
After you finish
Go to
Change the feature pack
Change the feature pack
You change the feature pack to convert the host protocol of your host ports.
Steps
1. From SANtricity System Manager, select Settings > System.
2. Under Add-ons, select Change Feature Pack.
3. Click Browse, and then select the feature pack you want to apply.
4. Type CHANGE in the field.
5. Click Change.
The feature pack migration begins. Both controllers automatically reboot twice to allow the
new feature pack to take effect. The storage array returns to a responsive state after the reboot
is complete.
6. Confirm the host ports have the protocol you expect.
a. From SANtricity System Manager, select Hardware.
b. Click Show back of shelf.
c. Select the graphic for either Controller A or Controller B.
d. Select View settings from the context menu.
e. Select the Host Interfaces tab.
f. Click Show more settings.
After you finish
Go to
Complete host protocol conversion
.
Complete host protocol conversion
After converting the protocol of the host ports, you need to perform additional steps before you
can use the new protocol.
Maintaining EF300 and EF600 Hardware
79
Host port protocol conversion

Table of Contents

Other manuals for NetApp E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp E Series and is the answer not in the manual?

NetApp E Series Specifications

General IconGeneral
Form Factor2U, 4U
Drive TypesSSD
Host InterfaceSAS, iSCSI, FC, IB
RAID LevelsRAID 0, 1, 5, 6, 10
Operating System CompatibilityWindows, Linux, VMware
Management SoftwareSANtricity

Related product manuals